top of page

TR-FRET Kits

Shopping Options:

Catalog number: SBB-KF0057, 400 wells

The kit uses ubiquitin labeled with either Europium-Cryptate or Cyanine5 as FRET pair donor and acceptor fluorophores respectively, completely eliminating the need for antibody based detection setups. Enzymatic incorporation of the labeled ubiquitins into chains conjugated onto XIAP leads to an increase in fluorescence emission at 665 nm (Emacceptor) and decrease at emission wavelength 620 nm (Emdonor).

Catalog number: SBB-KF0036, 400 wells

The kit uses ubiquitin labeled with either Europium-Cryptate or Cyanine5 as FRET pair donor and acceptor fluorophores respectively, completely eliminating the need for antibody based detection setups. 

Catalog number: SBB-KF0056, 400 wells

The kit uses ubiquitin labeled with either Europium-Cryptate or Cyanine5 as FRET pair donor and acceptor fluorophores respectively, completely eliminating the need for antibody based detection setups.

Catalog number: SBB-KF0030, 400 wells

The kit uses ubiquitin labeled with either Europium-Cryptate or Cyanine5 as FRET pair donor and acceptor fluorophores respectively, completely eliminating the need for antibody based detection setups. Enzymatic incorporation of the labeled ubiquitins into chains conjugated onto MDM2 leads to an increase in fluorescence emission at 665 nm (Emacceptor) and decrease at emission wavelength 620 nm (Emdonor).These proteins were expressed in E.coli.

Catalog number: SBB-KF0035, 400 wells

The kit uses ubiquitin labeled with either Europium-Cryptate or Cyanine5 as FRET pair donor and acceptor fluorophores respectively, completely eliminating the need for antibody based detection setups. Enzymatic incorporation of the labeled ubiquitins into chains conjugated onto ITCH leads to an increase in fluorescence emission at 665 nm (Emacceptor) and decrease at emission wavelength 620 nm (Emdonor).

Catalog number: SBB-KF0120, 400 wells

The kit uses ubiquitin labeled with either Europium-Cryptate or Cyanine5 as FRET pair donor and acceptor fluorophores respectively, completely eliminating the need for antibody based detection setups. Enzymatic incorporation of the labeled ubiquitins into chains conjugated onto CRBN leads to an increase in fluorescence emission at 665 nm (Emacceptor) and decrease at emission wavelength 620 nm (Emdonor).

South Bay Bio

We offer a variety of custom biochemistry services with an emphasis on assay development and custom protein labeling.

 

Our goal is to advance into lead identification & provide you with the tools and knowledge to succeed.

Custom Biochemistry
  • Assay design & development: TR-FRET, ELISA, Fluorescence Polarization

  • Protein & antibody labeling: Maleimide, NHS, Hydrazide coupling & more

  • Expression & purification: E. coli, Yeast, Insect, Mammalian

  • Protein characterization, enzyme kinetics, IC50 & Ki determination

Contact Us
CALL: (415) 935-3226
General Help:
support@south-bay-bio.com

Orders and Shipping:
orders@south-bay-bio.com

5941 Optical Court, Suite 229
San Jose, CA 95138

© 2025 by South Bay Bio LLC
bottom of page